أخبار
خدمة ممتازة عالية الجودة وعالية الأداء
البحث عن منتجالبحث عن منشور
خدمة ممتازة عالية الجودة وعالية الأداء
In the specialized field of optoelectronics, the DFB (Distributed Feedback) fiber coupled laser represents the pinnacle of semiconductor spectral control. While standard Fabry-Perot lasers allow multiple longitudinal modes to oscillate within the cavity—resulting in a broad, unstable spectrum—the DFB architecture forces the laser to operate on a single, precise frequency. This is not merely a preference for “cleaner” light; for applications such as Distributed Acoustic Sensing (DAS) or coherent optical communications, spectral purity is the fundamental enabler of system performance.
The transition from a multi-mode source to a single-frequency 1550nm DFB laser involves a radical shift in cavity physics. Instead of relying on the cleaved facets of the semiconductor chip to act as mirrors, a DFB laser incorporates a periodic structure—a Bragg grating—directly into the active region of the chip. This grating acts as a frequency-selective filter that only allows a single wavelength to undergo constructive interference. For engineers, the challenge lies in the realization of this grating and its subsequent coupling into a ليزر ليفي يحافظ على الاستقطاب system without introducing phase noise or mechanical instability.
The heart of the DFB laser is the internal Bragg grating. This grating is a periodic variation of the refractive index along the longitudinal axis of the laser cavity. The physics is governed by the Bragg condition:
$$\lambda_{Bragg} = 2 \cdot n_{eff} \cdot \Lambda$$
Where $\lambda_{Bragg}$ is the target wavelength, $n_{eff}$ is the effective refractive index of the waveguide, and $\Lambda$ is the period of the grating.

A perfectly uniform grating actually supports two modes symmetrically placed around the Bragg frequency. To ensure true single-mode operation, high-end 1550 nm DFB chips incorporate a $\lambda/4$ phase shift in the center of the grating. This shift creates a resonance at the exact Bragg wavelength, effectively suppressing the second mode and resulting in a Side Mode Suppression Ratio (SMSR) often exceeding 45 dB or even 50 dB.
From an engineering perspective, the quality of this grating—often fabricated via electron-beam lithography or holographic interference—determines the “Linewidth” of the laser. A narrow linewidth (typically <1 MHz for standard DFB, and <100 kHz for high-end variants) is essential because it directly dictates the coherence length of the light. In sensing, a narrower linewidth allows for measurements over much longer distances without losing the phase relationship of the signal.
The linewidth of a single frequency ليزر مقترن بالألياف is not zero. It is limited by phase noise, primarily caused by spontaneous emission of photons into the lasing mode. This is described by the modified Schawlow-Townes formula:
$$\Delta \nu = \frac{h \nu v_g^2 \alpha_m \alpha_{tot} (1 + \alpha_H^2)}{4 \pi P}$$
Where $\alpha_H$ is the Henry linewidth enhancement factor, which accounts for the coupling between refractive index and carrier density fluctuations.
To minimize this linewidth, manufacturers must optimize the “Quantum Well” design of the InGaAsP/InP layers to reduce the $\alpha_H$ factor. Additionally, the power $P$ in the cavity must be maximized, but this leads to a trade-off: higher power increases the risk of thermal gradients across the grating, which can cause frequency “chirp” or even mode-hopping. This is why the thermal engineering of the وحدة ليزر مقترنة بالألياف is as critical as the semiconductor physics itself.
When a DFB chip is integrated into a fiber-coupled optical receiver or transmitter system, the packaging must protect the spectral integrity of the source. The 14-pin Butterfly package is the industry standard for DFB lasers for several reasons:
In the DAS (Distributed Acoustic Sensing) market, the صمام ليزر ثنائي ليزر ضيق العرض الخطي is often the most expensive single component in the interrogator unit. It is tempting for system integrators to source lower-cost DFB modules. However, the “Cost of Quality” reveals itself in the signal-to-noise ratio (SNR) of the final system.
A low-cost DFB laser might have a linewidth of 5 MHz and an SMSR of 35 dB. While this seems sufficient for basic data transmission, in a DAS system used for pipeline monitoring, this 5 MHz linewidth results in a high “Phase Noise Floor.” This noise masks the tiny acoustic vibrations caused by a leak or a third-party intrusion. To compensate for a poor laser, the system developer must invest in more expensive, low-noise amplifiers and complex digital signal processing (DSP) algorithms. By contrast, starting with a premium, low-phase-noise 1550nm DFB laser significantly simplifies the downstream electronics and improves the “Detection Probability” of the system, ultimately lowering the total cost of the sensor network.
خلفية العميل:
An offshore wind farm operator required a Distributed Acoustic Sensing (DAS) system to monitor the integrity of subsea high-voltage power cables over a distance of 50 kilometers.
التحديات التقنية:
The primary challenge was the attenuation of the backscattered Rayleigh signal. Over 50km, the signal returning to the fiber-coupled optical receiver is incredibly weak.
المعلمات الفنية والإعدادات الفنية:
حل مراقبة الجودة (QC):
كل وحدة الليزر underwent “Linewidth Characterization” using the Delayed Self-Heterodyne (DSH) method with 25km of delay fiber. This ensured that only chips with a Lorentzian linewidth of <80 kHz were utilized. We also conducted “Frequency Stability” tests over 72 hours in a variable-temperature environment to ensure the TEC and thermistor were perfectly calibrated.
الخلاصة:
By implementing the ultra-narrow linewidth polarization maintaining fiber laser, the customer extended their sensing range to 55km without requiring additional optical amplifiers. The improved SMSR reduced “Coherent Fading” noise, allowing the system to detect cable vibrations with a resolution of 10 nanostrains—sufficient to identify early-stage mechanical failure of the cable armor.
| المعلمة | الوحدة | Standard DFB | Narrow Linewidth DFB | External Cavity (ECL) |
| طول الموجة المركزية | nm | 1550 ± 2 | 1550 ± 0.5 | 1550 ± 0.01 |
| عرض الخط (FWHM) | kHz | 1,000 – 5,000 | 50 – 500 | < 10 |
| SMSR | ديسيبل | > 35 | > 45 | > 55 |
| Output Power (Fiber) | ميجاوات | 10 – 40 | 10 – 60 | 10 – 30 |
| ضوضاء الشدة النسبية (RIN) | dB/Hz | -145 | -155 | -160 |
| Frequency Stability | MHz/°C | 12,000 (0.1nm) | < 1,000 (TEC) | < 100 (TEC) |
| Phase Noise Floor | rad/√Hz | $10^{-4}$ | $10^{-6}$ | $10^{-7}$ |
| نوع الحزمة | - | Coaxial / Butterfly | Butterfly | Butterfly / Chassis |
Q1: What is the difference between “Linewidth” and “Spectral Width”?
In the context of a distributed feedback laser, “Spectral Width” often refers to the broad envelope including side modes (measured at -20 dB), while “Linewidth” refers to the width of the central lase peak itself (measured as FWHM). For single-frequency lasers, the linewidth is the critical metric for coherence.
Q2: Why does a DFB laser need an internal isolator?
A DFB laser relies on an internal grating for feedback. Any external reflection (from a fiber tip or a mirror) acts as a “second cavity,” which interferes with the internal grating. This causes “Optical Chaos,” leading to sudden jumps in frequency and a massive increase in phase noise.
Q3: Can a 1550nm DFB laser be tuned?
Yes, but only slightly. By changing the temperature of the chip via the TEC, the refractive index of the semiconductor changes, shifting the Bragg wavelength by approximately 0.1nm per degree Celsius. Standard tuning ranges are ±1nm to ±2nm.
Q4: What is “Mode Hopping” and why is it a failure?
Mode hopping occurs when the laser suddenly jumps from the desired Bragg mode to a neighboring longitudinal mode. This causes a massive discontinuity in the sensor data. High-quality DFB engineering ensures “Kink-Free” and “Mode-Hop Free” operation across the entire current and temperature range.
Q5: How is linewidth measured accurately?
Since a 100 kHz linewidth is much narrower than the resolution of a standard Optical Spectrum Analyzer (OSA), we use “Delayed Self-Heterodyne” interferometry. The laser beam is split; one path is delayed by a long fiber (longer than the coherence length) and then recombined with the original beam to create a beat signal that can be analyzed by an RF spectrum analyzer.
في السعي لتحقيق التماسك الشديد، يتم تحديد أداء الصمام الثنائي الليزري ذي العرض الخطي الضيق من خلال نظرية شاولو-تاونز التي تربط العرض الطيفي بكثافة الفوتون داخل التجويف البصري ومعدل الانبعاث التلقائي...
عرض التفاصيلفي العالم الصارم للضوئيات الدقيقة، يمثل الانتقال من تجويف فابري-بيرو (FP) القياسي إلى الصمام الثنائي الليزري ذي العرض الخطي الضيق تحولاً جوهرياً في هندسة المرنان. فبينما يتأرجح ليزر أشباه الموصلات التقليدي في تجويف أشباه الموصلات...
عرض التفاصيلفي البيئات الصناعية عالية المخاطر — من وضع العلامات في مجال الطيران إلى تصنيع الأجهزة الطبية — غالبًا ما يحدد اختيار مصدر الضوء وقت تشغيل خط التجميع بأكمله. وقد برزت الصمامات الثنائية الليزرية المقترنة بالألياف كالحل المفضل ...
عرض التفاصيلفي تجميع الأجهزة القابلة للارتداء الحديثة — الساعات الذكية ونظارات الواقع المعزز وسماعات الأذن TWS — يتم التخلص تدريجياً من المواد اللاصقة واللحام بالموجات فوق الصوتية. المواد اللاصقة تتصلب ببطء شديد، والاهتزازات فوق الصوتية تدمر الميكروفونات والجيروسكوبات الحساسة MEMS. المعيار هو ...
عرض التفاصيل